Current position:Home » Products » Battery Test Equipment » Battery Load Bank
PITE3980 Battery Load Bank
It is significant to check battery capacity in a regular basis. And the only reliable way to measure the battery capacity is to carry out a discharge test which is a must-to-do job to energize standby batteries and extend their life span. PITE 3980 series DC load banks feature unique design and excellent performance that will facilitate your work for battery maintenance. It covers different types of batteries (1.2V, 2V, 6V and 12V). With different models, it has wide range of discharging like 24V, 48V, 110V, 220V and 380V. With optional DAC, discharging values of each cell could be viewed on the LCD display and computer simultaneously by using the PITE DataView software.
  • Design features
  • Product function
  • Technical parameter
  • Small weight, portable unit, convenient for onsite test
  • Customized models for smart selection of users from different industries
  • Optional wireless DAC enables its PC monitoring during measurement
  • It sets 4 conditions for auto shut-down of discharge: discharge time, discharge capacity, string voltage and cell voltage.
  • Continued discharge available when previous discharge is stop abnormally
  • Parallel connection of two units for higher discharge current
  • With DAC, it has real-time display of voltage for each cell
  • Can work with other load banks for assistant discharge
  • Can monitor the measurement of other load banks or battery chargers
  • Accurate data measurement with vivid waveforms
  • Auto sorting for lag-out batteries during discharging
  • Safe circuits avoids damage to battery when testing
  • Direct USB drive for convenient data transfer to PC
  • Powerful management software for data analyzing and report printing
  • Thermal cut-off and automatic overload protection
  • ● Verify discharge test
    The discharge monitor can continuously set the discharge current. According to the set discharge current constant current discharge, monitor the discharge process of the battery and a single voltage, measure the capacity of a single battery (check the capacity of the experiment).
    Various discharge stop condition settings:
    A, the total battery voltage B, single cell voltage C, the discharge time D, the discharge capacity
    A variety of single cell to adapt: 2V, 4V, 6V, 12V
    Wireless single cell voltage acquisition, a collection box can be accessed by 12 2V, 4V battery, 4 6V, 12V battery


    ● Fast measurement
    Short-term (10 to 20 minutes) discharge, rapid test of single cell internal resistance and discharge capacity, rapid identification of battery performance.


    ● After the power failure, the actual load on-line test the battery capacity
    When the power failure / actual load discharge, on-line automatic monitoring of single cell voltage, battery voltage and discharge current, record the discharge capacity of the battery to ensure the battery state of judgment.


    ● Current monitoring function (optional)
    When the power failure / actual load discharge, on-line automatic monitoring of single cell voltage, battery voltage and discharge current, record the discharge capacity of the battery to ensure that the battery state of judgment.


    ● Charging voltage monitoring function
    After the verification of the discharge without the need to dismantle the equipment and the battery can be charged after the whole process of monitoring, including: the entire group of charging voltage, charging voltage, charging time


    ● Backward battery recognition function (continuous discharge function)
    In the discharge process when a cell to discharge the lower threshold and the entire group voltage is still in the normal voltage can choose to suspend the discharge will continue to put forward after the discharge, so as not to put the battery over the battery for the future activation Provide scientific conditions. This function can pick out the first 6 to reach the lower threshold of the battery, because once more than 6 that the entire group of non-compliance of the battery.


    ● Continuous discharge function
    PITE3980 discharge monitor can also be divided into different working days of discharge work to facilitate the staff of the time.


    ● PC wireless monitoring function
    In 100m within the realization of PC-discharge monitoring system for wireless data monitoring, alarm function.


    ● Data management
    PITE3980 discharge monitor has perfect computer management analysis and monitoring software, powerful data processing functions, the use of advanced mathematical model, a number of battery measurements on the comprehensive calculation and analysis to accurately determine the battery performance, and query the battery real-time operating status And historical data, including the parameters, curves, and generate reports.

    1). AC 220V/110V, 50/60Hz;
    2). DC (optional for some models)
    Discharging Current
    Accuracy: 1%    Resolution: 0.1A or 0.5%
    Discharge voltage range
    48V: 10-55.2V      110V*: 10V-132V
    220V: 10-264V     380V: 10-437V
    Voltage Accuracy
    0.5%
    Sampling Interval
    5s –1min
    LCD Display
    128*64 pixel
    Temperature
    0℃~40℃
    Humidity
    5%~90% Relative humidity
    Safety standard
    CE market, EMC standard

    Dimension & Weight (main unit)*
    400*177*280 mm (Size: S, 11kg)
    520*202*355 mm (Size: M, 16kg)
    555*225*435 mm (Size: L, 21kg)
    603*400*740 mm (Size: XL, 43kg)
    740*400*730 mm (Size: XXL, 52kg)

    * 1). Dimension and weight depend on different models. Please refer to brochure of each model for details.
    * 2). In some countries, 110V is replaced by 120V (10-144V). And 220V is replaced by 240V (10V-288V).