Current position:Home » Products » Power Quality Analyzer » Power Quality Analyzer
Power Quality Analyzer
An Easy-to-use power quality tool is a "must-have" for any person who maintains or troubleshoots three phase power. PITE Three Phase Power Quality Analyzer helps you locate, predict, prevent and troubleshoot problems in power distribution systems. We offer a full range of trouble-shooters for the prevention and analyzing of the power quality problem. It is not only your problem solver, but also a money saver.
  • Design features
  • Product function
  • Technical parameter
  • Portable design and colorful touch screen
  • High-performance Li-battery for long time power supply
  • Could test 3-phase volt, null line volt, 3-phase current, null line current, etc.
  • Up to 50 times harmonic testing with frequency spectrum graph
  • Power testing: 3-phase apparent power, active/reactive power, power factor, and 3-phase electric power.
  • 3-phase unbalance testing with vivid chart
  • Record at least 40 times of surge current
  • Testing for wave motion, short-time flicker and long-time flicker
  • Record up to 40 times of sag and swell
  • Could have long-time record for basic (stable) power quality parameter. Recording time interval adjustable between 3 second and 30 minutes.
  • Digital oscilloscope, checking waveform for voltage and current signal
  • With PITE DataView software for convenient analyzing of testing result
  • Trouble-elimination: fast measurement and display on screen for trouble-shooting
  • Predictive maintenance: test to avoid power quality problem before malfunction happens
  • Service function: measurement for power quality before users lead-in
  • Long time analysis: recording function help find out unobvious and occasional malfunction
  • Load analysis: check quality of electric system before adding loads
  • Energy evaluation: evaluate energy consumption before installation of energy-saving facilities
  • Specifications

    Range

    Accuracy

    Volt/Amp/Hertz

    Volt: 10~700V (true rms)
    Amps: 0.5~3000A
    (true rms, with relevant current clamp)   Volt Peak: 0-1000V
    Crest factor: 0-10
    N current: 0.5~25A (true rms)
    Hertz: 40~70Hz

    Volts: ±0.5%
    Amps: ±0.5%
    Hertz: ±0.01Hz
    NOTE: Take frequency of Phase A as total testing frequency.

    Harmonic

    Volts: total harmonic +1~50th
    Amps: total harmonic +1~50th
    K-factor: 0-10

    Volts: ±0.1(%r)
    Amps: ±1%
    ±0.5%

    Power testing

    Active Power: 0.05~700KW
    Apparent Power: 0.05~700KVA
    Reactive Power: 0.05~700KVAR
    Power Factor: 0.00~1.00
    Active Energy: 0.01~10000kWh
    Apparent Energy: 0.01~10000kVAh
    Reactive Energy: 0.01~10000kVARh
    Average Power Factor: 0.00~1.00

    Active Power: ±1%
    Apparent Power: ±1%
    Reactive Power:±1%
    Power Factor: ±0.005
    Active Energy: ±1%
    Apparent Energy: ±1%
    Reactive Energy: ±1%h
    Average Power Factor: ±0.005

    Unbalance

    Fundamental Volts: 10~700V (true rms)
    Fundamental Amps: 0.5~1000A (True rms)
    Fundamental Hertz: 40~70Hz
    Phase Angle: 0~360°
    Unbalance: 0.0%~100%

    Volts: ±0.5%
    Amps: ±0.5%
    Hertz: ±0.01Hz
    Phase Angle: ±0.3°
    Volt unbalance:  ±0.2%
    NOTE: Take frequency of Phase A as total testing frequency.

    Data Recording

    Recording for: 3 phase voltage, current, null current, voltage harmonic
    (THD and 1~25 harmonics),
    current harmonics
    ( THD and 1~25 harmonics), unbalance, KW, KVA, KVAR, PF,
    flicker and fluctuation

    Time interval: 3s~30min adjustable
    Time duration: <960 hours

    Sags(Dips)/Swells

    Volts sag, Volts Swells and instant interruption

    Maximally could record 40 times

    Fluctuation

    Voltage Fluctuation:0.1%~10.0%

    ≤±5%

    Flicker

    Short-time and long-time flicker

    Short-time: ≤±5%

    Scope

    3-phase Volts, 4-wire Current, null volt and null current waveform

    Max Hertz: 200KHz
    Min Hertz: 100Hz